Electric Control Systems
comply with SY/T5053.2 and API Spec 16D standards and feature a fast plug-in facility, simplified automated controls with misoperation protection and a 120 minute backup battery. We can also supply to meet the ATEX explosion proof standard upon your request.

Features
- Uses advanced PLC and Profibus control technology to simplify and automate operation.
- Designed and manufactured to comply with SY/T5053.2 and API Spec 16D standards
- ATEX explosion-proof standard to meet European Security Standard CE available upon your request.
- 120 minute backup battery for normal operation in the event of sudden power loss.
- Stable working performance even under extreme working conditions.
- Driller’s panel displays operation status notice and features misoperation protection.
- Fast plug-in facility for easier installation.

Configuration Parameters of Electric Hydraulic Control System
| Model | Number of controlled objects | Accumulator unit | Explosion proof motor Power (Kw) | ||
|---|---|---|---|---|---|
| Total volume (L) | Available liquid volume (L) | Installation mode | |||
| FKDQ1600-14 | 14 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1600-12 | 12 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1600-10 | 10 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1440-14 | 14 | 60×24 | 720 | Side/rear | 18.5×2 |
| FKDQ1280-10 | 10 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-9 | 9 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-8 | 8 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-7 | 7 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1200-9 | 9 | 60×20 | 600 | Side/rear | 18.5×2 |
| FKDQ1200-8 | 8 | 60×20 | 600 | Side/rear | 18.5×2 |
| FKDQ960-8 | 8 | 60×16 | 480 | Side/rear | 18.5×2 |
| FKDQ960-7 | 7 | 60×16 | 480 | Side/rear | 18.5×2 |
| FKDQ800-8 | 8 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ 800-7 | 7 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ 800-6 | 6 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ720-7 | 7 | 60×12 | 360 | Side/rear | 18.5 |
| FKDQ 720-6 | 6 | 60×12 | 360 | Side/rear | 18.5 |
| FKDQ 640-6 | 6 | 40×16 | 320 | Side/rear | 18.5 |
| FKDQ 640-5 | 5 | 40×16 | 320 | Side/rear | 18.5 |
| FKDQ 480-5 | 5 | 40×12 | 240 | Side/rear | 18.5 |
| FKDQ 480-4 | 4 | 40×12 | 240 | Side/rear | 18.5 |
| FKDQ320-5 | 5 | 40×8 | 160 | Side/rear | 15 |
| FKDQ320-4 | 4 | 40×8 | 160 | Side/rear | 15 |
| FKDQ320-3 | 3 | 40×8 | 160 | Side/rear | 15 |
| FKDQ240-3 | 3 | 40×6 | 120 | Side/rear | 15 |
| FKDQ200-4 | 4 | 25×8 | 100 | Side/rear | 15 |
| FKDQ160-3 | 3 | 40×4 | 80 | Side/rear | 15 |
| FKDQ150-2 | 2 | 50×3 | 75 | Side/rear | 15 |
| FKDQ125-3 | 3 | 25×5 | 62.5 | Side/rear | 7.5/11 |
| FKDQ80-3 | 3 | 40×2 | 40 | Side/rear | 7.5 |
| FKDQ80-2 | 2 | 40×2 | 40 | Side/rear | 7.5 |
| FKDQ75-2 | 2 | 25×3 | 62.5 | Side/rear | 7.5 |
| FKDQ63-2 | 2 | 63×1 | 31.5 | Side/rear | 7.5 |
| FKDQ50-2 | 2 | 25×2 | 25 | Side/rear | 7.5 |
| FKDQ40-2 | 2 | 40×1 | 20 | Side/rear | 7.5 |
| FKDQ25-2 | 2 | 25×2 | 12.5 | Side/rear | 7.5 |
| FKDQ25-1 | 1 | 25×2 | 12.5 | Side/rear | 7.5 |
| Model | Pump system displacement | Rated operating pressure of the system (Mpa) | Maximum operating pressure of the system (Mpa) | |
|---|---|---|---|---|
| Triplex pump (mL/r) | Pneumatic pump (mL/ stroke) | |||
| FKDQ1600-14 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-12 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-10 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1440-14 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1280-10 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-9 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1280-7 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1200-9 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1200-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-7 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ800-8 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-7 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-6 | 80 | 120 | 21 | 31.5 |
| FKDQ720-7 | 80 | 120 | 21 | 31.5 |
| FKDQ 720-6 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-6 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-4 | 80 | 120 | 21 | 31.5 |
| FKDQ320-5 | 60 | 120 | 21 | 31.5 |
| FKDQ320-4 | 60 | 120 | 21 | 31.5 |
| FKDQ320-3 | 60 | 120 | 21 | 31.5 |
| FKDQ240-3 | 60 | 120 | 21 | 31.5 |
| FKDQ200-4 | 60 | 120 | 21 | 31.5 |
| FKDQ160-3 | 60 | 120 | 21 | 31.5 |
| FKDQ150-2 | 60 | 120 | 21 | 31.5 |
| FKDQ125-3 | 28 | – | 21 | 21 |
| FKDQ80-3 | 28 | – | 21 | 21 |
| FKDQ80-2 | 28 | – | 21 | 21 |
| FKDQ75-2 | 28 | – | 21 | 21 |
| FKDQ63-2 | 28 | – | 21 | 21 |
| FKDQ50-2 | 28 | – | 21 | 21 |
| FKDQ40-2 | 28 | – | 21 | 21 |
| FKDQ25-2 | 28 | – | 21 | 21 |
| FKDQ25-1 | 28 | – | 21 | 21 |
Main Technical Parameters of Electric Hydraulic Control System
| Normal pressure of the system: | 21 Mpa | 3000 psi |
|---|---|---|
| Pressure regulating range of the system: | 0~14 Mpa | 3000 psi |
| Nitrogen charging pressure of accumulator: | 7±0.7 Mpa | 3000 psi |
| Pressure switch setting range: | 18.9~21 Mpa | 2700~3000psi |
| Hydraulic/pneumatic switch setting range: | 18.9~21 Mpa | 2700~3000psi |
| Air supply pressure: | 0.65~0.8 Mpa | 93~115psi |
| Power supply: | 380±19V / 50Hz Optional as required by customers | |
| Control power supply: | 24V DC | |
| Battery capacity: | 10Ah | |
| Communication interface: | Profibus-Dp |
Functional Configuration of Electric Hydraulic Control System
| Model | Electric oil pump | Pneumatic oil pump | Manual oil pump | Alarm device | Standby nitrogen system | Protection house |
|---|---|---|---|---|---|---|
| FKDQ1600-14 | • | • | ◊ | • | ◊ | • |
| FKDQ1600-12 | • | • | ◊ | • | ◊ | • |
| FKDQ1600-10 | • | • | ◊ | • | ◊ | • |
| FKDQ1440-14 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-10 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-9 | • | • | ◊ | • | ◊ | • |
| FKDQ 1280-8 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-7 | • | • | ◊ | • | ◊ | • |
| FKDQ1200-9 | • | • | ◊ | • | ◊ | • |
| FKDQ1200-8 | • | • | ◊ | • | ◊ | • |
| FKDQ960-8 | • | • | ◊ | • | ◊ | • |
| FKDQ960-7 | • | • | ◊ | • | ◊ | • |
| FKDQ800-8 | • | • | ◊ | • | ◊ | • |
| FKDQ 800-7 | • | • | ◊ | • | ◊ | • |
| FKDQ 800-6 | • | • | ◊ | • | ◊ | • |
| FKDQ720-7 | • | • | ◊ | • | ◊ | • |
| FKDQ 720-6 | • | • | ◊ | • | ◊ | • |
| FKDQ 640-6 | • | • | ◊ | • | ◊ | • |
| FKDQ 640-5 | • | • | ◊ | • | ◊ | • |
| FKDQ 480-5 | • | • | ◊ | • | ◊ | • |
| FKDQ 480-4 | • | • | ◊ | • | ◊ | • |
| FKDQ320-5 | • | • | ◊ | • | ◊ | • |
| FKDQ320-4 | • | • | ◊ | • | ◊ | • |
| FKDQ320-3 | • | • | ◊ | • | ◊ | • |
| FKDQ240-3 | • | • | ◊ | • | ◊ | • |
| FKDQ200-4 | • | • | ◊ | • | ◊ | • |
| FKDQ160-3 | • | • | ◊ | • | ◊ | • |
| FKDQ150-2 | • | • | ◊ | • | ◊ | • |
| FKDQ125-3 | • | x | ◊ | • | ◊ | • |
| FKDQ80-3 | • | x | ◊ | • | ◊ | • |
| FKDQ80-2 | • | x | ◊ | • | ◊ | • |
| FKDQ75-2 | • | x | ◊ | • | ◊ | • |
| FKDQ63-2 | • | x | ◊ | • | ◊ | • |
| FKDQ50-2 | • | x | ◊ | • | ◊ | • |
| FKDQ40-2 | • | x | ◊ | • | ◊ | • |
| FKDQ25-2 | • | x | ◊ | • | ◊ | • |
| FKDQ25-1 | • | x | ◊ | • | ◊ | • |
| Model | Insulated House | Driller’s console | Auxiliary console | Pipe rack and hose | PN-T automatic recording system | Zero pressure starting system |
|---|---|---|---|---|---|---|
| FKDQ1600-14 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1600-12 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1600-10 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1440-14 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-10 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-9 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 1280-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1200-9 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1200-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ960-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ960-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ800-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 800-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 800-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ720-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 720-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 640-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 640-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 480-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 480-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ240-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ200-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ160-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ150-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ125-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ80-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ80-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ75-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ63-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ50-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ40-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ25-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ25-1 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
Note:
- Listed above are basic configurations of our products, where, “•” represents basic configuration and “◊” optional.
- The optional configuration here doesn’t mean that it is available in any model, which should be discussed at time of contract conclusion.
- Protection room width: 2100mm for common room and 2300mm for room with thermal insulation.
- Listed above are basic configurations, but special design and manufacturing can be provided upon request.
- The auxiliary driller’s console can be based on buttons or touch screen
- Pneumatic pump is not available to FKDQ series liquid control equipment. The remote console must be provided with air supply interface for pneumatic control.